Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Rev. chil. radiol ; 18(4): 157-162, 2012. ilus, tab
Article in Spanish | LILACS | ID: lil-665604

ABSTRACT

Objective. To validate the utility of 4D Blood Flow and Navier-Stokes equations to create relative pressure (RP) maps in the aorta and pulmonary artery (PA) in healthy volunteers and patients with repaired tetralogy of Fallot (TOF). Methods. A 4D flow sequence of whole heart and its major vessels was acquired in 10 healthy volunteers and 6 patients with repaired TOF. The root of the ascending aorta was used as the reference point to calculate RP along five different points of this area. In addition, relative pressure of both right and left PA was measured as correlated to absolute pressure. Results. Patients with repaired TOF showed greater pulmonary artery (PA) relative pressure differences between maximum and minimum values when compared to volunteers (p <0.05). Additionally, aortic relative pressures had an excellent correlation with published data, whether using 4D flow or by catheterization. Conclusions. 4D Flow MRI may represent a new non-invasive and non operator-dependent diagnostic tool in CV disease management.


Objetivo. Utilizar 4D Flow y las ecuaciones de Navier-Stokes para obtener mapas de presiones relativas (PR) en la Aorta y Arteria Pulmonar (AP) de voluntarios y pacientes con Tetralogía de Fallot reparada (TOFr). Métodos. En 10 voluntarios y 6 pacientes con TOFr se adquirió la secuencia 4D flow del corazón y sus principales vasos. La raíz de la Aorta Ascendente se utilizó como referencia para calcular las PR a esta zona en cinco puntos distintos. Además, se midió la PR de la AP derecha e izquierda respecto a la AP. Resultados. Los pacientes con TOFr tuvieron diferencias de PR entre los valores máximos y mínimos más grandes que los voluntarios en la AP (p<0,05). Adicionalmente, las PR de la aorta tuvieron una excelente correlación con datos publicados utilizando 4D flow y mediante cateterización. Conclusiones. 4D Flow podría constituir una nueva herramienta diagnóstica, no invasiva, ni operador dependiente, en el manejo de patologías CV.


Subject(s)
Middle Aged , Aorta, Thoracic/physiopathology , Pulmonary Artery/physiopathology , Magnetic Resonance Imaging , Tetralogy of Fallot/physiopathology , Blood Flow Velocity , Pressure
2.
Rev. chil. radiol ; 17(4): 183-191, 2011. ilus, graf, tab
Article in Spanish | LILACS | ID: lil-627524

ABSTRACT

Background. Increase in visceral fat is associated to the development of fatty liver and liver fibrosis. Hepatic elastography is a novel noninvasive method for assessing liver fibrosis. Objective. To evaluate the relationship between visceral adipose tissue volume (VAT), subcutaneous adipose tissue volume (SAT) as measured by Magnetic Resonance Imaging (MRI) and transient elastography (TrE) values using ARFI (Acoustic Radiation Force Impulse) in type 2 Diabetic Mellitus patients (DM2). Methods. We included 20 DM2 patients (mean age: 62 years, range: 55-75, mean weight: 77.8 kg, range: 61.5-97). Patients underwent an MRI study in a Philips Intera 1.5T scanner. MR imaging protocol included a spectral excitation sequence centered on the fat peak. The sequence included 32 cross sections, 7mm thick, from the diaphragmatic cupula to the inferior border of the kidney. VAT was measured by using the semiautomatic Image J software. Each patient underwent a hepatic elastograpy (HE); 10 ARFI measurements were performed in the right hepatic lobe. Finally, a statistical analysis was performed by applying Pearson correlation between abdominal fat volumes and ARFI scores Results. Mean VAT was 2472 +/- 861 cc, (1173-4020 cc), whilst the mean ARFI was 1.62 ± 0.8 m/s, (0.8-3.4 m/s). Correlations obtained were r=0.08 between VAT and ARFI (p=0.72); 0.13 between SAT and ARFI (p=0.57), and -0.06 between (VAT+SAT) and ARFI (p=0.77). By subdividing the sample universe, we observed that the group with ARFI scores greater than 1.6 m/s (7 patients) had a correlation of 0.63 between VAT and ARFI (p=0.12); of 0.66 between SAT and ARFI (p=0.10), and of 0.94 between VAT+SAT and ARFI (p=0.001). In the subgroup with ARFI values inferior to 1.6 m/s (13 patients), the correlation was of 0.11 between VAT and ARFI (p=0.71); of 0.26 between SAT and ARFI (p=0.38), and of 0.32 between ( VAT+SAT) and ARFI (p=0.28). When adjusted for gender, ARFI scores greater than.


Introducción. La acumulación de grasa visceral se asocia al desarrollo de enfermedad hepática. La elastografía hepática es un método novedoso no invasivo para evaluar fibrosis hepática. Objetivo. Evaluar la relación entre el volumen de tejido adiposo visceral (VAT), volumen de tejido adiposo subcutáneo (SAT) medido por resonancia magnética (RM), con índices de elastografía hepática (EH) utilizando ARFI (fuerza de impulso de radiación acústica) en pacientes con Diabetes Mellitus tipo 2 (DM2). Métodos. Fueron incluidos 20 pacientes (edad promedio: 62 años, rango: 55-75 años, peso promedio: 77,8 kg, rango: 61,5-97 kg) con DM2. Los pacientes se sometieron a un examen de RM en un resonador Philips Intera 1.5T. Al protocolo de RM se agregó una secuencia de excitación espectral centrada en el peak de grasa. La secuencia incluyó 32 cortes transversales, grosor 7mm, desde la cúpula diafragmática hasta el borde inferior renal. En las imágenes se midió VAT utilizando el software Image J (freeware). En cada paciente se realizó una EH, utilizando ARFI con 10 medidas en lóbulo hepático derecho. Finalmente, se realizó un análisis estadístico a través de la correlación de Pearson entre los volúmenes de grasa abdominal y ARFI. Resultados. El promedio de VAT fue 2472 +/- 861 cc, (1173-4020 cc), el promedio de ARFI fue 1,62 ± 0,8 m/s, (0,8-3,4 m/s). Se obtuvieron correlaciones de r=-0,08 entre VAT y ARFI (p=0,72), de 0,13 entre SAT y ARFI (p=0,57), y de -0,06 entre (VAT+SAT) con ARFI (p=0,77). Subdividiendo el universo muestral, se encontró que el grupo con ARFI mayor que 1,6 m/s (7 pacientes) obtuvo una correlación de 0,63 entre VAT y ARFI (p=0,12), de 0,66 entre SAT y ARFI (p=0,10), y de 0,94 entre (VAT+SAT) con ARFI (p=0,001). En el subgrupo con ARFI inferior a 1,6 m/s (13 pacientes) la correlación fue 0,11 entre VAT y ARFI (p=0,71), de 0,26 entre SAT y ARFI (p=0,38), y de 0,32 entre (VAT+SAT) y ARFI (p=0,28).


Subject(s)
Humans , Male , Female , Middle Aged , /pathology , Elasticity Imaging Techniques/methods , Intra-Abdominal Fat/anatomy & histology , Liver/pathology , Liver Cirrhosis/diagnosis , Fatty Liver/diagnosis , Magnetic Resonance Imaging , Risk Assessment , Adipose Tissue/anatomy & histology
3.
Rev. chil. radiol ; 17(3): 134-140, 2011. ilus
Article in Spanish | LILACS | ID: lil-608816

ABSTRACT

Purpose. To demonstrate the utility of 4D flow MR imaging for analyzing blood flow patterns and flow distribution in patients with congenital heart diseases. Methods: Six patients with congenital heart diseases were scanned using a standard cardiac MRI protocol, according to their condition. Additionally, 2D flow sequences of the great vessels, and a 4D flow sequence covering the entire heart were acquired. Flow patterns were visualized by using vector fields, streamlines and particle traces. Results: 4D flow technique depicted vortices and helical flow in the pulmonary artery of most patients, as well as in the aorta and superior vena cava of one patient with corrected aortic coarctation and a levoatrial cardinal vein. Conclusion: 4D flow MR imaging enables the identification of flow patterns difficult to detect with other diagnostic modalities. Comprehensive evaluation of flow patterns might help to understand the hemodynamic consequences of congenital heart diseases and their surgical procedures.


Objetivo. Demostrar la utilidad de 4D flow para el análisis de patrones y distribución de flujos en pacientes con cardiopatías congénitas. Métodos: Seis pacientes con cardiopatías congénitas fueron escaneados con un protocolo de resonancia magnética cardíaca estándar. Además se incluyeron secuencias de flujo 2D en los principales vasos del tórax y una secuencia 4D flow que cubría todo el corazón. Para la visualización de los patrones de flujo se emplearon vectores de velocidad, líneas de flujo y trazadores de partículas. Resultados: 4D flow reveló vórtices y hélices en la arteria pulmonar de la mayoría de los pacientes, y en la aorta y vena cava superior de un paciente con coartación aórtica reparada y vena cardinal levoatrial. Conclusiones: 4D flow permite identificar patrones de flujo en pacientes con cardiopatías congénitas, difíciles de observar con otros métodos diagnósticos. La evaluación de patrones de flujo podría contribuir a comprender las consecuencias hemodinámicas de diferentes cardiopatías congénitas.


Subject(s)
Humans , Male , Adolescent , Adult , Female , Child , Middle Aged , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/physiopathology , Magnetic Resonance Imaging/methods , Blood Flow Velocity/physiology , Aorta, Thoracic/physiopathology , Pulmonary Artery/physiopathology , Image Enhancement/methods , Aortic Coarctation/physiopathology , Regional Blood Flow , Vena Cava, Superior/physiopathology
4.
Rev. chil. radiol ; 15(supl.1): 10-16, 2009. ilus
Article in Spanish | LILACS | ID: lil-577473

ABSTRACT

Introduction: The acquisition process in magnetic resonance images (MRI) is slow. One approach to reduce the acquisition times is the reconstruction of undersampled data. i.e. to acquire less samples that those needed for standard application, and to reconstruct the unknown samples using mathematical algorithms. We propose to used reconstruction techniques for undersampled data based on Compressed Sensing (CS) to decrease the acquisition times, obtaining identical MRI as those obtained with all samples. Methods: We performed reconstructions of undersampled data obtained from phantoms and MRI with 60 percent, 55 percent and 50 percent of the samples. Results: When the number of samples was more that the double of pixels with non cero intensity, the reconstructions where identical to the original ones. For the MRI experiment, this was achieved with 60 percent of the samples, therefore obtaining a 40 percent of reduction in the acquisition time. Discussion: Our reconstruction technique based on CS is an effective way for reducing the acquisition times in MRI.


Introducción: El proceso de adquisición de imágenes por resonancia magnética (IRM) es lento. Una forma para disminuir los tiempos de adquisición es a través de reconstrucciones de datos submuestreados, es decir tomar menos muestras que las necesarias en aplicaciones estándares, y reconstruir las muestras faltantes a través de algoritmos matemáticos. Proponemos utilizar técnicas de reconstrucción de datos submuestreados basadas en técnicas de Compressed Sensing (CS) para disminuir los tiempos de adquisición, obteniendo imágenes idénticas a las obtenidas con todas las muestras. Métodos: Realizamos reconstrucciones de datos submuestreados de fantomas y IRM con 60 por ciento, 55 por ciento y 50 por ciento de las muestras. Resultados: Cuando el número de muestras fue mayor al doble del número de pixeles con intensidad cero, las reconstrucciones obtenidas fueron idénticas a las originales. Para las IRM esto se logró con 60 por ciento de las muestras, logrando reducciones del 40 por ciento en los tiempos de adquisición. Discusión: Nuestra técnica de reconstrucción basada en CS es una forma efectiva para reducir los tiempos de adquisición de IRM.


Subject(s)
Humans , Magnetic Resonance Imaging/methods , Image Processing, Computer-Assisted/methods , Image Enhancement/methods , Data Compression/methods , Time Factors , Phantoms, Imaging , Magnetic Resonance Imaging/instrumentation , False Negative Reactions , False Positive Reactions , Predictive Value of Tests
SELECTION OF CITATIONS